Skip to content
    Updated 28 November 2026 · reviewed by Jack Worley, Operations Director & Jamie Murray, CTO

    Cisco Room Kit and Room Navigator Not Working? Fixes by Symptom

    A Cisco Room Kit that will not register is often blocked from reaching a time server or Webex, not broken.

    Covers: Room Kit, Room Kit Mini, Room Kit Plus/Pro/EQ, Room Bar, Room Bar Pro, Board Pro, Room Navigator, Quad Camera

    Checked against RoomOS 11.14.1.7 (Room Bar, Cisco doc 222708); Cisco doc 226629 (Room Bar Pro, Teams Rooms mode); Webex network requirements rev. 18 Feb 2026; checked 28 Nov 2026. Each symptom links to the vendor page we verified it against.

    1. Cisco Room Kit not registered

    The device sits at "Registering", shows "Not able to connect to Webex service", a certificate or security error, a warning that the NTP server is unreachable, or a clock stuck in November 2015.

    1. 1Look at the date and time on the device. A clock set to November 2015 means it never reached a time server, which is the usual cause of the certificate and security errors.
    2. 2Ask your network team to allow outbound UDP port 123 (NTP) to the internet. Cisco lists UDP 123 as Network Time Protocol for all Webex devices (admin access needed). If you run NTP and DNS inside your own network, ports 53 and 123 do not need to be opened through the firewall.
    3. 3Cloud-registered Cisco devices also set their system time with an HTTPS request to activation.webex.com, so allow TCP 443 to Webex, including activation.webex.com (admin access needed).
    4. 4If a Meraki router is the DHCP server, it may advertise its own address in DHCP option 42 without hosting an NTP server. Cisco's fix is to run nslookup 0.tandberg.pool.ntp.org, set a custom DHCP option 42 to the first address returned, then reboot the device (admin access needed).
    5. 5If you use TLS inspection, Cisco's Webex network requirements say to open a service request with TAC to install your CA certificate into RoomOS. Otherwise the device may refuse the connection.

    If the clock is right and it still will not register, go to Cisco Room Kit offline in Control Hub below or the when to call us list.

    Source: Cisco: Unable to Register a Webex Room Device to Webex

    2. Cisco Room Kit offline in Control Hub

    Control Hub shows the device as offline, Local Device Control will not open, and you cannot reach its web page by IP address.

    1. 1In Control Hub, go to Devices, search for the device and open the Information icon. "Last seen online" tells you when it dropped, so you can match it to a power or network event.
    2. 2Check power and the network cable at the device, then check the "Time server not reachable" alert, which Control Hub raises when NTP fails. Fix that as in the first symptom.
    3. 3If the web page asks for a login you do not have, local user accounts may have been disabled during registration. Cisco names this as a cause of an offline device you cannot reach (admin access needed).
    4. 4To keep the existing configuration, open a TAC case. In Control Hub go to Devices, select the device, open Support and use Remote Access Key. Share the key only with the TAC engineer and never share the generated password.
    5. 5If you accept losing the configuration, factory reset the device (see the factory reset symptom below), delete the old Workspace in Control Hub, then register it again.

    If it stays offline after a reset on a known-good network, treat it as a hardware fault and see when to call us.

    Source: Cisco: Resolving Endpoint Offline Status in Control Hub

    3. Cisco Room Kit camera not working

    The device raises "No camera detected" or "Lost connection with camera".

    1. 1Know which camera you have. Cisco's installation guide covers the Quad Camera and Precision 60 on a Room Kit Pro. Other models differ, so check the guide for your model.
    2. 2On a Room Kit Pro, the Quad Camera video lead goes to HDMI Input Connector 1 and its control cable to Ethernet Connector 2 on the codec. A second Precision 60 uses HDMI Input Connector 2 and Ethernet Connector 3. Check these first, as a missed or loose control cable would stop the camera being detected.
    3. 3On a Room Kit Pro with a Quad Camera or Precision 60, camera control is Ethernet. Cisco's installation guide warns that a VISCA cable will cause severe damage to the camera, so never swap one in.
    4. 4On a Room Kit Pro, check the Quad Camera has its own power. It uses the grey 70 W adapter supplied with it. Leave slack in the cables so they do not loosen when the camera tilts fully forward.
    5. 5If Control Hub shows "Camera setup incomplete", finish the tilt adjustment on the device under Settings > Camera. For "Lost connection with camera", Cisco says to check the camera cable or download device logs and review camera.log (admin access needed).

    If the cables are right and a power cycle does not bring the camera back, it needs an engineer visit, see when to call us.

    Source: Cisco: Room Kit Pro Installation Guide (Quad Camera connections)

    4. Cisco Room Navigator not pairing

    The Navigator shows "The room device is missing software for this touch panel" and will not come online, even though the codec is reachable on the network.

    1. 1Cisco documents this for a Room Bar Pro running Teams Rooms mode; other models may differ. Reboot the codec. A Navigator connected directly to it restarts too. Cisco notes this error can appear after a Navigator factory reset or a codec upgrade.
    2. 2Check the Navigator can reach the codec on TCP port 443. Confirm you can open the codec web interface and SSH to it (admin access needed).
    3. 3Connect the Navigator straight to the codec or Room Bar PoE port, bypassing the building network, to rule out a network fault.
    4. 4Upgrade the codec from its web interface or Control Hub. The upgrade pushes the software to the Navigator (admin access needed).
    5. 5If it still fails, collect the logs from Issues & Diagnostics > System Logs and check the softwareupgrade, peripherals and application logs. Cisco says to factory reset the codec (Issues & Diagnostics > System Recovery > Factory Reset) and, if needed, the Navigator with the pinhole on its back (admin access needed).

    Cisco lists an RMA of the Navigator for the rare hardware fault, so see when to call us.

    Source: Cisco: Navigator error "The room device is missing software for this touch panel" (226629, Room Bar Pro)

    5. Cisco Room Navigator touch panel not responding

    The Navigator is stuck on connecting, or Control Hub shows the alert "Touch panel required".

    1. 1Check the Ethernet cable between the Navigator and the device. This is Cisco's suggested fix for the "Touch panel required" alert.
    2. 2The Navigator is powered over PoE only, with no mains option. Plug it into the codec or Room Bar PoE port directly, rather than through a switch, to tell a panel fault from a network or codec fault.
    3. 3Try a known-good cable and, if you can, a different PoE port.
    4. 4If Control Hub shows "Touch panel(s) count check", connect the number of panels the device expects, or have an admin update the Peripherals Profile TouchPanels setting (admin access needed).
    5. 5Reboot the codec so a directly connected Navigator restarts with it, then follow the pairing symptom above if the software message appears.

    A panel that stays dead on a known-good direct cable is a hardware fault, see when to call us.

    Source: Cisco: Device alerts in Control Hub

    6. Cisco Room Bar shutting down by itself

    The device goes offline at random with no warning, stays off until someone presses the power button, and Control Hub may show a high temperature warning.

    1. 1In Control Hub, go to Devices, search for the device and note "Last seen online" from the Information icon, so you can match the outage to the room's conditions.
    2. 2Check the room. For the Room Bar, Cisco's operating range is 0 to 35 degrees C ambient and 10 to 90 percent relative humidity. Cisco also says to place it where nothing blocks the ventilation holes, to check for dust or debris on the ventilation ports, and to check the internal fans are working if possible.
    3. 3Feel whether the unit is unusually hot, and compare with a similar device in another room. In Cisco's worked case, moving the Room Bar to a cooler room stopped the shutdowns.
    4. 4Check the "High temperature" and "System fan not working" alerts in Control Hub. We found no published fix for High temperature. For System fan not working, Cisco says to contact your Cisco technical support representative.
    5. 5After it returns, collect a log bundle. Entries from thermal_control around the outage time show a critical temperature and a thermal shutdown (admin access needed).

    Cisco field notice FN74300 lists certain Room Bar units with no workaround and a replacement process, so see when to call us.

    Source: Cisco: Video endpoint shut down due to high temperature (222708)

    7. Cisco Room Kit factory reset

    You need to wipe a Room Kit, Room Kit Mini, Room Bar or Room Navigator, for example after a handover or when you cannot log in.

    1. 1Understand the design. Cisco's Room Kit Administrator Guide (CE9.15, an older software release) says the device relies on CEC to switch the display back to its own input, and that the screen must be CEC compatible with CEC enabled on the screen itself.
    2. 2On a unit with a touch panel (Navigator or Touch 10), go to Settings and choose Factory Reset. On boards without a touch panel, use the Settings button in the top-right corner of the screen.
    3. 3Check the device's CEC setting in its video output configuration (see the administrator guide for your software release), and make sure it is not turned off (admin access needed).
    4. 4Test with one short, certified HDMI lead straight to the display. Control Hub raises "Daisy chained HDMI cable detected" (use a single Cisco HDMI cable straight from the codec to the display) and "Reversed optical HDMI cable detected" (disconnect the cable and reconnect it the other way around).
    5. 5If it only misbehaves at wake, start a call or share content and see whether the display switches to the device input.

    If the reset does not complete or the pinhole does nothing, the unit needs an engineer, see when to call us.

    Source: Cisco: Room Kit Administrator Guide (CE9.15), CEC section

    8. Cisco Room Kit TV shows no signal when it wakes

    The room display powers on but shows "No signal", or sits on its own TV tuner input, until a call starts or someone shares content.

    1. 1Understand the design. Cisco says the device relies on CEC to switch the display back to its own input when a call starts, and that the screen must be CEC compatible with CEC enabled on the screen itself.
    2. 2Enable CEC in the display's own menu. Manufacturers use their own names for it, such as Viera Link or EasyLink, so check the display manual.
    3. 3On the device, make sure CEC Mode is On for the video output connector the display uses. If Control Hub shows the "HDMI CEC mode off" alert, set CEC mode back to On (admin access needed).
    4. 4Test with one short, certified HDMI lead straight to the display. Control Hub raises "Daisy chained HDMI cable detected" and "Reversed optical HDMI cable detected" for those faults, and each needs the cable changed.
    5. 5If it only misbehaves at wake, start a call or share content. The device should then switch the display to its input, which is expected behaviour on some display models.

    If the display never picks up the device input even in a call, check the cable and the display with another source, then see when to call us.

    Source: Cisco: Room Kit Administrator Guide (CE9.15), CEC section

    When to stop and call an engineer

    • ·The Room Kit, Room Bar or Quad Camera has no picture or no power after the cables, power adapter and a full factory reset have been checked.
    • ·A Room Bar shuts itself down more than once, or Control Hub shows the high temperature or fan alert, which may fall under Cisco field notice FN74300 and need a replacement.
    • ·A Room Navigator will not pair after a codec upgrade, a direct cable and a reset, which Cisco says may need the Navigator replaced.
    • ·The device cannot register and the cause sits in the firewall, proxy, TLS inspection or DHCP, which only your network admin or a TAC case can change.
    • ·The device is offline, local accounts are disabled and nobody holds the admin login or Control Hub access to recover it.
    • ·The unit is physically damaged, or the pinhole reset does nothing.

    Our engineers support Cisco Room Kit, Room Bar and Room Navigator rooms on Teams, Zoom, Meet and Webex, whether we installed them or not. Tell us what you are seeing and we take it from here.

    Quick answers

    The most common cause is that it cannot reach a time server, so its clock is wrong and certificates fail. Cisco lists outbound UDP 123 for NTP and HTTPS to Webex as requirements. Check the date on the device first, then ask your network team to allow both. A wrong DHCP option 42 value can cause the same fault.
    Use the touch panel, going to Settings and choosing Factory Reset, or press the pinhole with a pin or paper clip for 10 to 15 seconds. The pinhole is on the back or bottom and may sit under a plastic cap. A reset wipes configuration and files, so delete the old Workspace in Control Hub before registering again.
    No. The Room Navigator is powered over PoE Ethernet and has no separate mains option. It connects to the codec or Room Bar PoE port, or to a PoE switch port. If it will not connect, plug it directly into the codec or Room Bar to separate a panel fault from a network fault.
    On a Room Kit Pro the Quad Camera needs an HDMI lead for video and an Ethernet cable for control, so a missing or loose control cable would stop it being detected. Other models use different cameras, so check your model's guide. Cisco's Room Kit Pro guide warns never to use a VISCA cable, which can severely damage the camera.